Related Experiment Video
Updated: Jun 19, 2026

10:39
Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Strehl ratio and visibility in long-baseline stellar interferometry.
Optics Letters
|October 28, 2009
Summary
Adaptive optics Strehl ratio (S) and interferometry visibility (V) are compared. For high Strehl ratios, V approximately equals S, but at low Strehl ratios, visibility is underestimated by the Strehl ratio.
Area of Science:
- Astronomy and Astrophysics
- Optical Engineering
Background:
- Adaptive optics (AO) and optical interferometry are key astronomical techniques.
- Strehl ratio (S) is standard in AO, while visibility (V) is crucial for interferometry.
Purpose of the Study:
- Investigate the relationship between Strehl ratio (S) and visibility (V).
- Determine how well S predicts V in different atmospheric turbulence conditions.
Main Methods:
- Simulations of atmospheric turbulence.
- Analytical formulation of the relationship between S and V.
- Analysis under Kolmogorov turbulence assumptions.
Main Results:
- For high Strehl ratios (S), visibility (V) is approximately equal to S.
- At low Strehl ratios, S underestimates the actual V.
- Discrepancy increases as Strehl ratio decreases.
Conclusions:
- The Strehl ratio is a reliable indicator of visibility only under high Strehl conditions.
- Interferometry practitioners should be cautious when using S to infer V at low Strehl ratios.
- Further research may refine the relationship for low Strehl regimes.
Related Concept Videos
Flame Photometry: Overview
Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
Atomic Emission Spectroscopy: Interference
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
Infrared (IR) Spectroscopy: Overview
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
Flame Photometry: Lab
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
IR Spectrometers
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...

