Related Experiment Video
Updated: Jun 19, 2026

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Flexural modulus, flexural strength, and stiffness of fiber-reinforced posts
Veridiana R Novais1, Paulo S Quagliatto, Alvaro Della Bona
1Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, MG, Brazil.
Background:
The radiopacity degree of posts is not enough for adequate visualization during radiographic analyses. Glass fiber post with stainless steel reinforcement has been fabricated in an attempt to overcome this limitation.
Aim:
This study was designed to determine the influence of this metal reinforcement on the post mechanical properties.
Materials And Methods:
This study evaluated flexural modulus (E), flexural strength (sigma), and stiffness (S) of five different fiber post systems (n = 5): RfX (Reforpost Glass Fiber RX; Angelus, Londrina, PR, Brazil); RG (Reforpost Glass Fiber, Angelus); RC (Reforpost Carbon Fiber, Angelus); FP (Fibrekor Post; Jeneric Pentron Inc., Wallingford, CT, USA); and CP (C-Post; Bisco Dental Products, Schaumburg, IL, USA), testing the hypothesis that the insertion of a metal reinforcement (RfX) jeopardizes the mechanical properties of a glass fiber post. Posts were loaded in three-point bending using a testing machine with a crosshead speed of 0.5 mm/min.
Results:
The results were statistically analyzed using one-way ANOVA and Tukey's multiple range tests (a = 0.05). Mean and standard deviation values of E (GPa), s (MPa), and S (N/mm) were as follows: RfX: 10.8 +/- 1.6, 598.0 +/- 52.0, 132.0 +/- 21.9; RG: 10.6 +/- 1.0, 562.0 +/- 24.9, 137.8 +/- 5.5; RC: 15.9 +/- 2.4, 680.5 +/- 34.8, 190.9 +/- 12.9; FP: 10.9 +/- 1.4, 586.8 +/- 21.9, 122.4 +/- 17.3; CP: 6.3 +/- 1.7, 678.1 +/- 54.2, 246.0 +/- 41.7. Carbon fiber posts showed the highest mean s values (P < 0.05). In addition, RC showed the highest mean E value and CP showed the highest mean S value (P < 0.05).
Conclusion:
The hypothesis was rejected since the metal reinforcement in the glass fiber post (RfX) does not decrease the mechanical property values. Posts reinforced with carbon fibers have a higher flexural strength than glass fiber posts, although all posts showed similar mechanical property values with dentin.
More Related Videos
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
09:54Measuring the Mechanical Properties of Glass Fiber Reinforcement Polymer Composite Laminates Obtained by Different Fabrication Processes
Published on: June 30, 2023
Related Concept Videos
Fiber Reinforced Concrete
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Design of Prismatic Beams for Bending
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...