Related Experiment Video
Updated: Jun 18, 2026

07:46
Setting Limits on Supersymmetry Using Simplified Models
Published on: November 15, 2013
Is the X(3872) production cross section at sqrt[s]=1.96 TeV compatible with a Hadron molecule interpretation?
C Bignamini1, B Grinstein, F Piccinini
1INFN Pavia, Via A. Bassi 6, Pavia, I-27100, Italy.
Physical Review Letters
|November 13, 2009
Summary
The X(3872) exotic hadron is likely a molecule composed of D0 and D*0 particles. This study estimates its production rate at the Fermilab Tevatron, comparing it with experimental data.
Area of Science:
- Particle Physics
- Hadron Spectroscopy
Background:
- The X(3872) is classified as an exotic hadron, challenging conventional quark models.
- Its internal structure remains a subject of theoretical debate.
Purpose of the Study:
- To investigate the molecular hypothesis for the X(3872) by estimating its prompt production cross section.
- To quantitatively assess the D0D(*0) molecular interpretation using experimental data.
Main Methods:
- Theoretical estimation of the prompt production cross section for the X(3872) assuming a D0D(*0) molecular state.
- Comparison of the estimated cross section with experimental data from the Collider Detector at Fermilab (CDF).
Main Results:
- The study provides quantitative constraints on the D0D(*0) molecular model of the X(3872).
- A comparison with CDF data offers compelling evidence for or against this molecular interpretation.
Conclusions:
- The findings allow for significant conclusions regarding the nature of the X(3872) as a molecular state.
- This research contributes to understanding exotic hadrons and their production mechanisms.
Related Concept Videos
¹H NMR: Complex Splitting
A proton M that is coupled to a proton X results in doublet signals for M. However, NMR-active nuclei can be simultaneously coupled to more than one nonequivalent nucleus. When M is coupled to a second proton A, such as in styrene oxide, each peak in the doublet is split into another doublet.
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied first.
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied first.
Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule
In the AX proton spin system, proton A can sense the two spin states of a coupled proton X, resulting in a doublet NMR signal with two peaks of equal (1:1) intensity. When proton A is coupled to two equivalent protons (AX2 spin system), the spin states of each X can be aligned with or against the external field, creating three possible scenarios. This results in a 1:2:1 triplet signal, where the central peak corresponds to the chemical shift of A and is twice as large or intense as the others.
¹H NMR Signal Multiplicity: Splitting Patterns
When protons A and X are coupled, their nuclear spin energy levels are slightly modified. This is because the energy required to excite proton A to a spin state parallel to proton X is slightly different from the energy required for it to become anti-parallel to spin X. Consequently, there are two possible excitation frequencies for A (A1 and A2), depending on the spin state of X, and vice versa. The mutual nature of coupling implies that the difference between frequencies A1 and A2, indicated...
Spin–Spin Coupling Constant: Overview
In bromoethane, the three methyl protons are coupled to the two methylene protons that are three bonds away. In accordance with the n+1 rule, the signal from the methyl protons is split into three peaks with 1:2:1 relative intensities. The methylene protons appear as a quartet, with the relative intensities of 1:3:3:1.
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must have a...
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must have a...
Mass Analyzers: Overview
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
¹H NMR: Long-Range Coupling
The coupling interactions of nuclei across four or more bonds are usually weak, with J values less than 1 Hz. While these are usually not observed in spectra, the presence of multiple bonds along the coupling pathway can result in observable long-range coupling.
In alkenes, spin information is communicated via σ–π overlap, as seen in allylic (four-bond) and homoallylic (five-bond) couplings. These coupling interactions are stronger when the σ bond is parallel to the alkene π orbitals.
In alkenes, spin information is communicated via σ–π overlap, as seen in allylic (four-bond) and homoallylic (five-bond) couplings. These coupling interactions are stronger when the σ bond is parallel to the alkene π orbitals.

