Related Experiment Video
Updated: Jun 18, 2026

Robotic Myotomy and Partial Fundoplication for Achalasia
Published on: August 11, 2023
Esophagogastric junction distensibility after fundoplication assessed with a novel functional luminal imaging probe
Monika A Kwiatek1, Kahrilas Kahrilas, Nathaniel J Soper
1Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, IL 60611-2951, USA. monika.kwiatek@gmail.com
Objective:
The aim of the study was to compare the esophagogastric junction (EGJ) compliance in response to controlled distension in fundoplication (FP) patients and controls using the functional luminal imaging probe (FLIP).
Background:
FP aims to replicate normal EGJ distensibility. FLIP is a new technology that uses impedance planimetry to measure intraluminal cross-sectional area (CSA) during controlled distension.
Methods:
Ten controls and ten FP patients were studied with high-resolution esophageal pressure topography (HREPT) and then the FLIP placed across the EGJ. Deglutitive and interdeglutitive EGJ distensibility was assessed with volume-controlled distension. The FLIP measured eight CSAs spaced 4 mm apart within a cylindrical saline-filled bag along with the corresponding intrabag pressure.
Results:
The EGJ formed an hourglass shape during distensions with the central constriction at the diaphragmatic hiatus. The distensibility of the hiatus was significantly greater during deglutitive relaxation in both subject groups, but FP patients exhibited reduced EGJ distensibility and compliance compared to controls. During the interglutitive period, the corresponding increase in intrabag pressures at larger volumes were also greater in FP patients implying a longer segment of EGJ constriction. The EGJ distensibility characteristics did not correlate with HREPT measures.
Conclusions:
FLIP technology was used to compare EGJ distensibility in FP patients and control subjects. The least distensible locus within the EGJ was always at the hiatus. EGJ distensibility was significantly reduced, and the length of constriction increased in FP patients. Future FLIP studies will compare patients with and without post-FP dysphagia and gas bloat, symptoms suggestive of an overly restrictive FP.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...
Gastric Emptying
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Esophageal Strictures-I: Introduction
Etiology
The primary cause of esophageal strictures is long-standing gastroesophageal reflux disease (GERD), accounting for about 70 to 80% of adult cases. Chronic acid reflux can lead to injury and scarring of the esophageal lining, culminating in...
