Related Experiment Video
Updated: Jun 18, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0
Ronald Boellaard1, Mike J O'Doherty, Wolfgang A Weber
1Department of Nuclear Medicine and PET Research, VU University Medical Centre, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands. r.boellaard@vumc.nl
This guideline establishes minimum standards for acquiring and interpreting [18F]-fluorodeoxyglucose (FDG) PET/CT scans. It focuses on optimizing diagnostic quality and quantitative information for physicians and physicists.
Area of Science:
- Nuclear Medicine
- Radiology
- Medical Imaging
Background:
- Positron Emission Tomography-Computed Tomography (PET/CT) with [18F]-fluorodeoxyglucose (FDG) is a crucial imaging modality.
- Standardization is needed for consistent and reliable FDG PET/CT examinations.
Purpose of the Study:
- To establish a minimum standard for the acquisition and interpretation of FDG PET/CT scans.
- To guide physicians and physicists in performing, interpreting, and documenting quantitative FDG PET/CT examinations.
- To optimize the diagnostic quality and quantitative information derived from FDG PET/CT.
Main Methods:
- Development of a guideline based on current best practices.
- Focus on technical aspects of image acquisition.
- Emphasis on interpretation protocols for quantitative analysis.
Main Results:
- A comprehensive guideline for FDG PET/CT acquisition and interpretation.
- Recommendations for optimizing image quality and quantitative accuracy.
- Standardized approach to reporting quantitative FDG PET/CT data.
Conclusions:
- Adherence to this guideline will enhance the reliability and consistency of FDG PET/CT imaging.
- Improved diagnostic accuracy and quantitative assessment are expected.
- This guideline serves as a foundational standard for nuclear medicine professionals.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...