Comparison of visual-tactile, radiographic, and histologic diagnoses of subgingival crown margin caries- an in vitro
Julia-Gabriela Wittneben1, Axel Zöllner, Axel F Wright
1Advanced Graduate Prosthodonctics Program, Department of Restorative Dentistry and Biomaterials Sciences, Havard School of Dental Medicine, Boston, MA, USA. julia.wittneben@zmk.unibe.ch
Abstract:
The purpose of this study was to investigate the accuracy of diagnosing interproximal subgingival caries at crown margins. A total of 32 subgingival interproximal crown margin areas were examined by 10 clinicians (n = 320) using conventional diagnostic methods on extracted, crowned teeth mounted in a specially designed cast. Crown margins were located 1.5 mm below the level of the artificial gingiva. Clinical and radiographic diagnoses were compared to the histopathologic findings for each site. Both visual-tactile and radiographic evaluations revealed a weak diagnostic accuracy for interproximal subgingival crown margin caries.