Objective:
To compare the diagnostic accuracy of Rb-82 myocardial perfusion three-dimensional (3D) PET with and without prompt-gamma compensation (PGC).
Methods And Results:
Retrospective, single center study of 76 patients who had rest and adenosine stress Rb-82 myocardial perfusion 3D PET. All studies were acquired using a Siemens Biograph-40 PET/CT scanner and were reconstructed with and without PGC. Fifty-seven patients (mean age 63 +/- 11 years, 26 men) had coronary angiography within 40 days of Rb-82 imaging. Nineteen patients (mean age 43 +/- 7 years, 10 men) had low likelihood of coronary artery disease (CAD). All PET images were scored by consensus of two blinded readers on a standard 5-point scale using a 17-segment left ventricular model. A normal PET test was defined as a summed stress score of less than four. Obstructive CAD at coronary angiography was used as the gold-standard and was defined as luminal stenoses > or =50% in one or more major coronary arteries. The prevalence of obstructive disease at coronary angiography was 68% (39/57). The mean summed stress score was 12 +/- 12 for PGC images and was 18 +/- 14 for non-PGC images. Sensitivity and specificity for obstructive CAD were 90% (95% CI 88-99) and 72% (95% CI 52-93) for PGC images and 95% (95% CI 88-100) and 22% (95% CI 3-41) for non-PGC images.
Conclusion:
PGC in Rb-82 3D PET improves the specificity for obstructive CAD at coronary angiography with no significant loss in sensitivity.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET