Related Experiment Video
Updated: Jun 18, 2026

Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse
Published on: October 24, 2018
Calculating mixed venous saturation during veno-venous extracorporeal membrane oxygenation
Joshua L Walker1, Jonathan Gelfond, Lee Ann Zarzabal
1University of Texas Health Science Center at San Antonio, Division of Surgery, Department of Cardiothoracic Surgery, San Antonio, Texas 78229, USA. walkerj3@uthscsa.edu
Introduction:
Recirculation (R), the shunting of arterial blood back into to the venous lumen, commonly occurs during veno-venous extracorporeal membrane oxygenation (VV-ECMO) and renders the monitoring of the venous line oxygen saturation no longer reflective of patient mixed venous oxygen saturation (S(V)O(2)). Previously, we failed to prove the hypothesis that, once R is known, it is possible to calculate the S(V)O(2) of a patient on VV-ECMO. We hypothesize that we can calculate S(V)O(2) during VV-ECMO if we account for and add an additional correction factor to our model for dissolved oxygen content. Therefore, the purpose of this study is to derive a more accurate model that will allow clinicians to determine S(V)O(2) during VV-ECMO when ultrasound dilution is being used to quantify R.
Methods:
Using an extracorporeal circuit primed with fresh porcine blood, two stocks of blood were produced; (1) arterial blood (AB), and (2) venous blood (VB). To mimic recirculation, the AB and VB were mixed together in precise ratios using syringes and a stopcock manifold. Six paired stock AB/VB sets were prepared. Two sets were mixed at 20% R increments and 4 sets were mixed at 10% R increments. The partial pressure of oxygen (pO(2) ) and oxygen (O(2)) saturation of the stock blood and resultant mixed blood was determined. The original model was modified by modeling the residual errors with linear regression.
Results:
When using the original model, as the partial pressure of arterial oxygen (P(a)O( 2)) of the stock AB increased, the calculated S(V)O(2) was higher than actual, especially at higher R levels. An iteration of the original model incorporating the P(a)O(2) level (low, medium, high) and R was derived to fit the data.
Conclusions:
The original model using R and circuit saturations for the calculation of S(V)O( 2) in VV-ECMO patients is an oversimplification that fails to consider the influence of the high pO(2) of arterial blood during therapy. In the future, further improvements in this model will allow clinicians accurately to calculate S(V)O(2) in conjunction with recirculation measurements.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...