Real-time MR thermometry for monitoring HIFU ablations of the liver
Andrew B Holbrook1, Juan M Santos, Elena Kaye
1Department of Bioengineering, Stanford University, Stanford, California, USA. aholbrook@stanford.edu
Abstract:
A high-resolution and high-speed pulse sequence is presented for monitoring high-intensity focused ultrasound ablations in the liver in the presence of motion. The sequence utilizes polynomial-order phase saturation bands to perform outer volume suppression, followed by spatial-spectral excitation and three readout segmented echo-planar imaging interleaves. Images are processed with referenceless thermometry to create temperature-rise images every frame. The sequence and reconstruction were implemented in RTHawk and used to image stationary and moving sonications in a polyacrylamide gel phantom (62.4 acoustic W, 50 sec, 550 kHz). Temperature-rise images were compared between moving and stationary experiments. Heating spots and corresponding temperature-rise plots matched very well. The stationary sonication had a temperature standard deviation of 0.15 degrees C compared to values of 0.28 degrees C and 0.43 degrees C measured for two manually moved sonications at different velocities. Moving the phantom (while not heating) with respect to the transducer did not cause false temperature rises, despite susceptibility changes. The system was tested on nonheated livers of five normal volunteers. The mean temperature rise was -0.05 degrees C, with a standard deviation of 1.48 degrees C. This standard deviation is acceptable for monitoring high-intensity focused ultrasound ablations, suggesting real-time imaging of moving high-intensity focused ultrasound sonications can be clinically possible.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...