Development of the device to detect SPO(2) in the field
Yoshiaki Kanaeda1, Kazushige Magatani
1Tokai University, Japan.
Abstract:
In case of disaster such as a severe earthquake, many sufferers will be generated at the disaster area. In this situation, we have a problem that sometimes rescuers are also injured by disaster. In order to avoid such damage, various kinds of rescue robots are being developed and used. Most of them are developed to remove debris and obstacles. Using these robots, we can find sufferers and rescue them in safety. However, rescue robots cannot asses a sufferer's condition at the disaster area. If some vital signs can be measured by a rescue robot, the efficiency of rescue operation will be greatly improved. Our objective of this study is the development of measurement methods that can assess sufferer's vital signs at the disaster area by a rescue robot. In this paper, we will talk about a developed method that can measure pulse and SPO(2). Most of SPO(2) measurement methods are using red and infrared ray that penetrate the skin. However, reflected rays are used to measure these vital signs in our method. Intensity of red and infrared ray is controlled automatically in order to measure vital signs stably. Using this method, these vital signs can be measured only by touching the sufferer's skin with a developed sensor. We think that this method will be powerful and useful to rescue sufferers at disaster area.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...