Sample Preparation for Probe Electrospray Ionization Mass Spectrometry
Published on: February 19, 2020
Hand-held mass spectrometer for environmentally relevant analytes using a variety of sampling and ionization methods
Nathaniel L Sanders1, Ewa Sokol, Richard H Perry
1Department of Chemistry, Purdue University, West Lafayette, IN 47907-2084, USA.
Abstract:
A recently developed hand-held, rectilinear ion trap mass spectrometer, capable of performing in situ analysis, has been evaluated for a variety of environmentally relevant analytes. Different sampling and ionization methods were implemented, demonstrating the considerable versatility of this instrument. A discontinuous (viz. pulsed) atmospheric pressure inlet (DAPI) was used to introduce externally-generated analyte ions. Nitro compounds were ionized by electrosonic spray ionization (ESSI) yielding the protonated and sodiated forms of the molecular ion, as well as fragment ions. The amines 2,2,6,6-tetramethylpiperidine, triethylamine and 2,6-diphenylpyridine showed low parts per billion (ppb) detection limits. Vapor phase external ionization was used to examine the chemical warfare simulant dimethyl methylphosphonate and the insect repellant N,N-diethyl-m-toluamide. Membrane introduction mass spectrometry (MIMS) was used as the introduction system for hydrophobic analytes using a selectively permeable (polydimethylsiloxane) membrane placed within the vacuum manifold with subsequent ionization of the thermally desorbed neutral compounds inside the ion trap. MIMS allowed the quantitation of trace levels (a few ppb) of fluorinated compounds in the vapor phase. MIMS was also applied to the quantitation of aqueous polycyclic aromatic hydrocarbons (PAH's) with limits of detection again in the low ppb range for naphthalene, acenaphthene, anthracene and phenanthrene.
More Related Videos
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometers
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
Mass Analyzers: Overview
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview