Related Experiment Video
Updated: Jun 17, 2026

Increasing Pulmonary Artery Pulsatile Flow Improves Hypoxic Pulmonary Hypertension in Piglets
Published on: May 11, 2015
Doppler flow patterns in the evaluation of pulmonary hypertension
Carmen Ginghină1, Denisa Muraru, Aurora Vlădaia
1Prof. Dr. C.C. Iliescu Institute of Cardiovascular Diseases, Bucharest, Romania. carmenginghina2001@yahoo.com
Abstract:
Pulmonary arterial hypertension is defined as a group of diseases characterised by a progressive increase in pulmonary vascular load, leading to marked increase in pulmonary artery pressure, right ventricular failure and premature death. Given the nonspecific nature of its early symptoms and signs, pulmonary arterial hypertension (PAH) is often diagnosed in its advanced stages. Although clinical assessment is essential when initially evaluating patients with suspected PAH, echocardiography is a key screening tool in the diagnostic algorithm, because, in comparison with invasive measurements, it has the advantages of being safe, portable, and repeatable. Therefore, Doppler echo is the modality most frequently used in pulmonary hypertension patients. Several echocardiographic techniques centered on the Doppler principle (both conventional Doppler parameters and tissue Doppler imaging) used in the assessment of PAH magnitude and its cardiac effects are presented in this paper. They provide important data on the severity, possible causes and consequences of pulmonary hypertension, both initially and during follow-up, therefore having the ability to estimate disease progression, prognosis, or to monitor therapeutic response. Doppler echocardiography allows to noninvasively estimate systolic pulmonary arterial pressure (SPAP), mean and end-diastolic pulmonary arterial pressure, as well as the quantification of right ventricular (RV) function and the evaluation of pulmonary vascular resistance (PVR).
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...