Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Pulse wave imaging for noninvasive and quantitative measurement of arterial stiffness in vivo
Jonathan Vappou1, Jianwen Luo, Elisa E Konofagou
1Ultrasound and Elasticity Imaging Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
Background:
Arterial stiffening is recognized to be associated with increased cardiovascular mortality and to be a major cause of several cardiovascular complications. Pulse wave velocity (PWV) has been widely accepted to be a reliable and robust measure of arterial stiffness. In this article, the novel ultrasound-based pulse wave imaging (PWI) method is hereby proposed for visualization of the pulse wave during its propagation and for calculation of the PWV.
Methods:
The PWV is estimated by measuring the spatiotemporal variation of the pulse wave-induced displacement of the arterial wall within the imaged segment. The method is compared to mechanical testing on aortic phantoms in order to evaluate its reliability and accuracy, and in vivo results are presented on normal abdominal aortas (N = 11).
Results:
Good agreement was found with mechanical testing on phantoms (r(2) = 0.92), showing the reliability of the method. In vivo average PWV and Young's modulus were found to be equal to 4.4 +/- 0.6 m/s and 108 +/- 27 kPa, respectively.
Conclusions:
Reliability and in vivo feasibility of the proposed PWI method were demonstrated in this study. Its simplicity of use and its capability of providing regional PWV render PWI a valuable tool for quantitative assessment of arterial stiffness. The utility of the method in a clinical setting has yet to be established and is part of an ongoing clinical study.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical indicator...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: