Unrecognized basilic vein variation leading to complication during basilic vein transposition arteriovenous fistula
C L Kaiser1, J E Anaya-Ayala, N Ismail
1Department of Cardiovascular Surgery, Division of Vascular Surgery, Methodist DeBakey Heart and Vascular Center, The Methodist Hospital, 6550 Fannin Street, Ste 1401, Houston, TX 77030, USA.
Introduction:
Knowledge about variations of the venous arm anatomy is limited despite its importance for a successful arteriovenous fistula creation.
Report:
We describe a complication of a basilic vein transposition (BVT) resulting from failure to recognize aberrant anatomy. The brachial-basilic junction was located in an unusual position near the antecubital fossa leading to inadvertent distal brachial vein ligation and transposition of basilic and the proximal and unusually unpaired brachial vein.
Discussion:
This case highlights the prevalence of anomalies of upper extremity veins and the need for thorough Duplex vein mapping before surgery for the preservation and planning of future access.
Related Concept Videos
Hemodialysis I: Introduction
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Peripheral Artery Disease V: Postoperative Nursing Management
Veins of Upper Limbs
The deep venous system is primarily composed of the ulnar and radial veins. The ulnar vein, which drains the fingers through the superficial palmar venous arches, and the radial vein, which serves the palms via the deep palmar...
Venous Thrombosis III: Interprofessional Care
Varicose Veins II: Diagnostic Studies and Interprofessional Care