Evaluation of intra- and interobserver variability and repeatability of tibial plateau angle measurements with
Marcos D Unis1, Ann L Johnson, Dominique J Griffon
1Small Animal Surgery Department, University of Illinois College of Veterinary Medicine, Urbana, IL, USA. munis@vet.k-state.edu
Objective:
To compare the intra- and interobserver variability occurring when observers with differing experience levels measure tibial plateau angles (TPAs) with a novel digital radiographic projection program (tibial plateau leveling osteotomy [TPLO] planning program), the Kodak Picture Archiving and Communications System (PACS), and standard sized printed films (SF).
Study Design:
Cross-sectional study.
Sample Population:
Dogs (n=36) with cranial cruciate ligament (CCL) rupture that had a TPLO.
Methods:
Six observers, divided into 3 equal groups based on experience level, measured TPA on 36 digitally captured radiographic images of tibiae of dogs clinically affected with CCL rupture. Each observer used 3 methods of measuring TPA and repeated the measurements 3 times with each method. The intra- and interobserver variability was compared using the coefficient of variation.
Results:
Averaged over all replications and images, there was no significant difference (P>.05) in the average variability occurring with each method for all but 1 observer. There was no effect of experience level on measurement variability; however, interobserver variability was significantly less with measurements made with the PACS and TPLO planning program compared with measurements made from SF (P<.05).
Conclusions:
Repeated measurements of TPA made using digital images and computer-based measurement programs were significantly less variable between observers than those made from images printed on standard radiographic films.
Clinical Relevance:
Digital radiography and computer-based measurement programs are effective for determining the TPA, allowing less variability in measurements compared with SF. The ability to manipulate the image may allow better identification of anatomic landmarks.