Related Experiment Video

Updated: Jun 15, 2026

Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing
08:12

Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing

Published on: March 13, 2013

Refractive-index measurements of single micron-sized carbon particles

A B Pluchino, S S Goldberg, J M Dowling

    Applied Optics
    |March 18, 2010
    PubMed

    Abstract:

    The differential scattering cross section for single carbon particles is measured in the visible. The data are mathematically inverted to obtain the complex index of refraction and particle radius.

    More Related Videos

    Measurement of Particle Size Distribution in Turbid Solutions by Dynamic Light Scattering Microscopy
    09:16

    Measurement of Particle Size Distribution in Turbid Solutions by Dynamic Light Scattering Microscopy

    Published on: January 9, 2017

    Implementation of a Reference Interferometer for Nanodetection
    16:11

    Implementation of a Reference Interferometer for Nanodetection

    Published on: April 26, 2014

    Related Experiment Videos

    Last Updated: Jun 15, 2026

    Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing
    08:12

    Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing

    Published on: March 13, 2013

    Measurement of Particle Size Distribution in Turbid Solutions by Dynamic Light Scattering Microscopy
    09:16

    Measurement of Particle Size Distribution in Turbid Solutions by Dynamic Light Scattering Microscopy

    Published on: January 9, 2017

    Implementation of a Reference Interferometer for Nanodetection
    16:11

    Implementation of a Reference Interferometer for Nanodetection

    Published on: April 26, 2014

    Related Concept Videos

    Total Internal Reflection Fluorescence Microscopy01:05

    Total Internal Reflection Fluorescence Microscopy

    Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.

    Articles linked to this work by shared authors, journal, and citation graph.

    Surface waves and the radiative properties of micron-sized particles.

    Applied optics·2010

    Refractive indices of germanium, silicon, and fused quartz in the far infrared.

    Applied optics·2010

    Metal mesh interference filters for the far infrared.

    Applied optics·2010

    A high-resolution, far infrared double-beam lamellar grating interferometer.

    Applied optics·2010

    Comprehensive model of the photophoretic force on a spherical microparticle.

    Optics letters·2009

    Molecular spectroscopy of a single aerosol particle.

    Optics letters·2009

    Heterodyne interferometric phase demodulation system based on hysteresis alignment for CNC machine tool positioning errors.

    Applied optics·2026

    Optimization of ground-based optical network configuration for geosynchronous orbit observation.

    Applied optics·2026

    Effect of laser pulse width (ns-fs) on laser-induced damage thresholds of a CMOS photodetector.

    Applied optics·2026

    Two-dimensional synchronous stray light detection and correction method for imaging spectrometers.

    Applied optics·2026

    Misalignment-induced aberration compensation technique based on feature extraction and optimization of spot images at an arbitrary single field point.

    Applied optics·2026

    Top-profile-prior-constrained inversion for bottom-parameter reconstruction of extreme ultraviolet mask phase defects.

    Applied optics·2026

    Dual-energy CT-generated bone marrow edema maps improve reader confidence without changing fracture detection rates in bony pelvis trauma.

    Skeletal radiology·2026

    Scattering properties of Intralipid modeled using dependent scattering theory.

    Journal of biomedical optics·2026

    Beyond plaque and stenosis: Coronary inflammation imaging with the fat attenuation index.

    Journal of cardiology·2026

    Association of Diagonal Earlobe Crease (Frank's Sign) with Intracranial Aneurysm Rupture at Small Sizes.

    Brain sciences·2026

    Multilevel Lumbar CT Attenuation Beyond L1: Comparison with QCT-Derived Volumetric Bone Mineral Density and Prevalent Fragility Fracture Status in a Diagnostic Referral Cohort.

    Diagnostics (Basel, Switzerland)·2026

    Feasibility and characteristics of contrast-enhanced lung ultrasound in the diagnosis of pulmonary embolism in hospitalized patients.

    Medicina clinica·2026
    See all related articles
    JoVE
    x logofacebook logolinkedin logoyoutube logo
    ABOUT JoVE
    OverviewLeadershipBlogJoVE Help Center
    AUTHORS
    Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
    LIBRARIANS
    TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
    RESEARCH
    JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
    EDUCATION
    JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
    Terms & Conditions of Use
    Privacy Policy
    Policies
    Jove
    Visualize
    Contact Us