Related Experiment Video
Updated: Jun 14, 2026

In Vivo Imaging and Tracking of Technetium-99m Labeled Bone Marrow Mesenchymal Stem Cells in Equine Tendinopathy
Published on: December 9, 2015
Tc-99m sestamibi thyroid imaging in patients on chronic amiodarone treatment: a comparison with Tc-99m pertechnetate
Glaucia Celeste Rossatto Oki1, Denise Engelbrecht Zantut-Wittmann, Allan de Oliveira Santos
1Division of Nuclear Medicine, Department of Radiology, School of Medical Sciences, University of Campinas, Campinas, Brazil.
Purpose Of The Report:
To compare thyroid imaging using Tc-99m sestamibi with the standard Tc-99m pertechnetate scintigraphy in patients on chronic use of amiodarone.
Materials And Methods:
A total of 23 patients on oral amiodarone for at least 4 months had thyroid scintigraphy and uptake measurement using Tc-99m pertechnetate and Tc-99m sestamibi. Thyroid function was evaluated by measuring serum concentrations of thyrotropin, free thyroxine, and free triiodothyronine, and antithyroglobulin and antithyroperoxidase antibodies.
Results:
Ten of the 23 patients were euthyroid, 9 hypothyroid, and 4 hyperthyroid, with normal, increased, and decreased serum thyrotropin, respectively. All euthyroid patients had markedly decreased thyroid Tc-99m pertechnetate uptake and normal or slightly increased Tc-99m sestamibi uptake, except for one patient who had increased uptake of both radiotracers. One of the 4 hyperthyroid patients had Graves' disease and markedly increased thyroid uptake of both tracers. The other 3 hyperthyroid patients had normal or decreased Tc-99m pertechnetate uptake and increased Tc-99m sestamibi uptake. Differently than expected, all 9 hypothyroid patients had normal or increased uptake of both radiopharmaceuticals.
Conclusions:
This study suggests that Tc-99m sestamibi may be an alternative tracer for thyroid scintigraphy and uptake measurement of patients on chronic use of amiodarone. Tc-99m sestamibi seems to be better than Tc-99m pertechnetate for the scintigraphic evaluation of the thyroid of euthyroid and hyperthyroid patients.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...

