Related Experiment Video
Updated: Jun 13, 2026

Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
Contrast-enhanced whole-heart coronary MRA using Gadofosveset 3.0 T versus 1.5 T
Maria Prompona1, Clemens Cyran, Konstantin Nikolaou
1Klinikum Grosshadern, Ludwig Maximilians Universität München Marchioninistr., Germany. mariadoctor@hotmail.com <mariadoctor@hotmail.com>
Rationale And Objectives:
To compare contrast-enhanced coronary magnetic resonance angiography (MRA) at 3.0 T with the same technique performed at 1.5 T using the contrast agent gadofosveset.
Materials And Methods:
In this prospective randomized study, 19 healthy male volunteers (mean age 28 years, mean weight 79.8 kg), after signing informed consents, underwent contrast-enhanced inversion recovery three-dimensional fast low angle shot (FLASH) MRA at 1.5 and at 3.0 T. Prospective electrocardiogram-triggering was combined with adaptive respiratory gating. For contrast-enhanced images, the intravascular contrast agent gadofosveset was used. Acquisition time, signal-to-noise ratio (SNR) of coronary blood, contrast-to-noise ratio (CNR) between coronaries and adjacent myocardium or epicardial fat and image quality were analyzed for statistical differences by using a two-tailed paired-sample t-test. The ratio calculations were based on measurements performed on the raw data and the image quality was blinded and independently evaluated by two experienced radiologists using a five-point scale.
Results:
The mean values for the acquisition time were 14.58 +/- 0.1 minutes at 1.5 T and 16.40 +/- 0.2 minutes at 3.0 T. Overall SNR of all evaluated coronary segments proved higher at 3.0 T compared to 1.5 T (74.0 +/- 42.1 at 3.0 T vs. 50.2 +/- 20.2 at 1.5 T, P = .04). Overall CNR between coronaries and myocardium was significantly increased at 3.0 T in comparison to 1.5 T (40.1 +/- 21.9 at 3.0 T vs. 24.4 +/- 17.2 at 1.5 T, P = .01). Between the two methods, no significant difference in overall CNR between coronaries and epicardial fat was observed (P = .08, NS). The 3.0 T MRA demonstrated superior overall image quality with respect to 1.5 T (2.28 +/- 0.71 at 3.0 T vs. 1.92 +/- 0.38 at 1.5T, P = .004).
Conclusion:
The use of higher field strength, 3.0 T instead of 1.5 T, resulted in similar CNR between coronaries and epicardial fat, higher SNR values and CNR between blood and myocardium, as well as an improved overall image quality, when gadofosveset in combination with electrocardiogram and respiratory triggering for coronary MRA was used.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography
Magnetic Resonance Imaging