Related Experiment Video
Updated: Jun 13, 2026

Microfluidic Model of Necrotizing Enterocolitis Incorporating Human Neonatal Intestinal Enteroids and a Dysbiotic Microbiome
Published on: July 28, 2023
Heterotrophic bacterial growth on hoses in a neonatal water distribution system
Sylvie Buffet-Bataillon1, Martine Bonnaure-Mallet, Armelle de la Pintiere
1Service de Bacteriologie, Virologie et Hygiene Hospitaliere, Pole Microorganismes et Hygiene Hospitaliere, CHU de Rennes, France. sylvie.buffet-bataillon@chu-rennes.fr
Abstract:
After preliminary tests indicated an increased number of heterotrophic bacteria, we investigated possible sources of contamination in a neonatal intensive care unit (NICU) water distribution system. Scanning electron microscopic examination of flexible metallic hoses associated with the system revealed the presence of a biofilm; partial 16S rDNA sequencing revealed that the biofilm contained Blastomonas natatoria. Purgation of the water system three times a day, reinforced faucet cleaning, decreasing the cold water temperature to 12 degrees , and six repeated chlorinations at concentrations as high as 2 mg/L were not sufficient to eradicate the bacterial contamination. Replacing all of the rubber-interior flexible metallic hoses with teflon-lined hoses followed by heating the water to 70 degrees successfully controlled the bacteria.
Related Concept Videos
Oxygen Requirements and Growth Patterns
Microbial Growth Media
Designing Growth Media for Bioreactors
Microbial Nutrition
Bacterial Growth Curve