Related Experiment Video
Updated: Jun 12, 2026

Cardiopulmonary Bypass in a Mouse Model: A Novel Approach
Published on: September 22, 2017
Simultaneous automatic control of oxygen and carbon dioxide blood gases during cardiopulmonary bypass
Berno J E Misgeld1, Jürgen Werner, Martin Hexamer
1Department of Biomedical Engineering, School of Medicine, Ruhr University, Bochum, Germany. berno.misgeld@rub.de
Abstract:
In this work an automatic control strategy is presented for the simultaneous control of oxygen and carbon dioxide blood gas partial pressures to be used during cardiopulmonary bypass surgery with heart-lung machine support. As the exchange of blood gases in the artificial extracorporeal lung is a highly nonlinear process comprising varying time delays, uncertainties, and time-varying parameters, it is currently being controlled manually by specially trained perfusionist staff. The new control strategy includes a feedback linearization routine with augmented time-delay compensation and two external linear gain-scheduled controllers, for partial oxygen and carbon dioxide pressures. The controllers were robustly tuned and tested in simulations with a detailed artificial lung (oxygenator) model in cardiopulmonary bypass conditions. Furthermore, the controllers were implemented in an ex vivo experiment using fresh porcine blood as a substitute fluid and a special deoxygenation technique to simulate a patient undergoing cardiopulmonary bypass. Both controllers showed robust stability during the experiments and a good disturbance rejection to extracorporeal blood flow changes. This automatic control strategy is proposed to improve patient's safety by fast control reference tracking and good disturbance rejection under varying conditions.
More Related Videos
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...

