Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Linear Approximation in Frequency Domain01:26

Linear Approximation in Frequency Domain

Linear systems are characterized by two main properties: superposition and homogeneity. Superposition allows the response to multiple inputs to be the sum of the responses to each individual input. Homogeneity ensures that scaling an input by a scalar results in the response being scaled by the same scalar.
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear.
IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next sampling...
IR Frequency Region: X–H Stretching01:24

IR Frequency Region: X–H Stretching

In IR spectroscopy, signals produced by the X−H bonds (such as C−H, O−H, or N−H) can be observed in the frequency range of  2700–4000 cm–1. The C−H stretching vibration forms sharp bands in the region 2850–3000 cm–1. The presence of the O−H stretching vibration leads to the forming of an absorption band in the frequency range 3650–3200 cm−1. At the same time, N−H stretching can be confirmed by absorption bands in the 3500–3100 cm−1 range. Even though both O−H and N−H bonds vibrate at a similar...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations01:08

IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations

Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single stretching vibration...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Trajectory analysis of sleep disorders and anxiety-depression in female breast cancer patients undergoing chemotherapy: based on group-based Multi-Trajectory Model and machine learning.

BMC medical informatics and decision making·2026
Same author

A Multi-Segmented Vectoring Nozzle Configuration Inspired by the Mating Wheel of Damselfly.

Biomimetics (Basel, Switzerland)·2026
Same author

Physics-driven deep learning photoacoustic tomography.

Fundamental research·2026
Same author

Training effect of a deep learning-based blended teaching model on ECMO transport for ICU nurses: a prospective, parallel-group, randomized controlled trial.

BMC nursing·2026
Same author

Prevention and management of nosocomial infections in patients undergoing extracorporeal membrane oxygenation: a summary of best evidence.

Frontiers in medicine·2026
Same author

Enhydrin from yacon attenuates atherosclerosis by modulating the FABP5/PPARγ/ABCA1 axis: An integrated multi-omics and in vivo validation.

Biochimica et biophysica acta. Molecular and cell biology of lipids·2026
Same journal

Gaussian-modulated continuous-variable quantum key distribution over 60 km fiber using an integrated silicon photonic receiver.

Optics letters·2026
Same journal

E2E-OCT: end-to-end joint learning model using optical coherence tomography images for vocal cord leukoplakia diagnosis.

Optics letters·2026
Same journal

Holographic generation of panoramic 3D scenes by concave ellipsoidal mirror reflection.

Optics letters·2026
Same journal

Dual-pilot phase recovery with pair-wise maximum-ratio combining for coherent PONs.

Optics letters·2026
Same journal

Mapping the whispering gallery modes of a CaF<sub>2</sub> disk resonator with half-tapered fibers to estimate the fundamental mode volume.

Optics letters·2026
Same journal

Quantitative estimation of deep-subwavelength scale via dark-field scattering axial energy concentration decay profiles.

Optics letters·2026
See all related articles

Related Experiment Video

Updated: Jun 12, 2026

Implementation of a Reference Interferometer for Nanodetection
16:11

Implementation of a Reference Interferometer for Nanodetection

Published on: April 26, 2014

Regularized frequency-stabilizing method for single closed-fringe interferogram demodulation.

Chao Tian1, Yongying Yang, Shuna Zhang

  • 1State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, 38 Zheda Road, Hangzhou 310027, China.

Optics Letters
|June 3, 2010
PubMed
Summary
This summary is machine-generated.

This study introduces a fast, regularized method for demodulating interferograms. The technique efficiently recovers continuous phase maps without needing phase unwrapping, proving effective in simulations and experiments.

More Related Videos

A Multimodal Wide-Field Fourier-Transform Raman Microscope
06:48

A Multimodal Wide-Field Fourier-Transform Raman Microscope

Published on: December 30, 2025

Micro/Nano-scale Strain Distribution Measurement from Sampling Moir&#233; Fringes
06:56

Micro/Nano-scale Strain Distribution Measurement from Sampling Moiré Fringes

Published on: May 23, 2017

Related Experiment Videos

Last Updated: Jun 12, 2026

Implementation of a Reference Interferometer for Nanodetection
16:11

Implementation of a Reference Interferometer for Nanodetection

Published on: April 26, 2014

A Multimodal Wide-Field Fourier-Transform Raman Microscope
06:48

A Multimodal Wide-Field Fourier-Transform Raman Microscope

Published on: December 30, 2025

Micro/Nano-scale Strain Distribution Measurement from Sampling Moir&#233; Fringes
06:56

Micro/Nano-scale Strain Distribution Measurement from Sampling Moiré Fringes

Published on: May 23, 2017

Area of Science:

  • Optical metrology
  • Signal processing
  • Image analysis

Background:

  • Interferogram demodulation is crucial for quantitative phase imaging.
  • Existing methods can be computationally intensive or require phase unwrapping.
  • Frequency stabilization is key for accurate phase recovery.

Purpose of the Study:

  • To develop a simple and fast regularized frequency-stabilizing method for interferogram demodulation.
  • To recover continuous phase maps efficiently from single interferograms.
  • To eliminate the need for post-processing phase unwrapping.

Main Methods:

  • A regularized frequency-stabilizing approach was developed.
  • A cost function was established using prior knowledge for phase recovery.
  • The method directly estimates the phase field, optimizing a cost function.

Main Results:

  • The proposed method demonstrated fast computation.
  • Continuous phase maps were successfully recovered.
  • Computer simulations and experimental results validated the method's rapidity and efficiency.

Conclusions:

  • The regularized frequency-stabilizing method offers a simple and efficient solution for interferogram demodulation.
  • The technique provides continuous phase maps, simplifying downstream analysis.
  • This approach is suitable for both open- and closed-fringe interferograms.