Related Experiment Video
Updated: Jun 12, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Good outcome and valve function despite Medtronic-corevalve underexpansion
Hasan Jilaihawi1, Anita Asgar, Raoul Bonan
1Department of Interventional Cardiology, Montreal Heart Institute, Quebec, Canada.
Severe aortic stenosis in an elderly patient was successfully treated with transcatheter aortic valve implantation, demonstrating good outcomes despite stent frame underexpansion. This approach offers excellent symptomatic recovery for high-risk surgical candidates.
Area of Science:
- Cardiology
- Interventional Cardiology
- Cardiac Surgery
Background:
- Severe calcific aortic stenosis and bicuspid aortic valve disease pose significant challenges, particularly in elderly patients with comorbidities.
- Conventional surgical valve replacement is often contraindicated in frail patients with poor left ventricular function and high surgical risk scores.
- Transcatheter aortic valve implantation (TAVI) offers a less invasive alternative for managing severe aortic stenosis in high-risk populations.
Observation:
- An 80-year-old female patient with severe calcific aortic stenosis and a bicuspid aortic valve was evaluated for TAVI due to ineligibility for conventional surgery.
- A 29-mm Medtronic-Corevalve bioprosthesis was successfully implanted via a transfemoral approach.
- Despite significant underexpansion of the stent frame's inflow portion, hemodynamic parameters were satisfactory, with an adequate aortic valve area and acceptable gradients.
Findings:
- The patient experienced early and sustained improvement in New York Heart Association (NYHA) functional class post-TAVI.
- Valvular function remained stable at the 2-year follow-up, indicating durable bioprosthetic performance.
- Hemodynamic assessment revealed a satisfactory aortic valve area (1.3 cm²/m²) and acceptable gradients (peak 23 mmHg, mean 16 mmHg).
Implications:
- Gross underexpansion of the Medtronic-Corevalve stent frame does not necessarily compromise bioprosthetic function or clinical outcomes.
- TAVI can achieve excellent symptomatic recovery and durable results even in complex cases with challenging valve anatomy and device deployment.
- This case underscores the importance of functional assessment and hemodynamic parameters in evaluating TAVI success, even in the presence of deployment variations.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Aortic Regurgitation III: Medical Management
Mitral Stenosis III: Medical Management
Mitral Regurgitation III: Medical Management
Mitral Valve Prolapse II: Assessment and Management
Mitral Stenosis I: Introduction