Modified repair in patients with Ebstein's anomaly
Nicole Nagdyman1, Peter Ewert, Takeshi Komoda
1Departments of Congenital Heart Defects and Pediatric Cardiology, Deutsches Herzzentrum Berlin, Augustenburger Platz 1, 13353 Berlin, Germany. nagdyman@dhzb.de
The Journal of Heart Valve Disease
|June 30, 2010
Summary
This study shows that a modified tricuspid valve repair technique for Ebstein's anomaly offers good long-term clinical results, improving patient outcomes without right ventricular plication.
Area of Science:
- Cardiovascular Surgery
- Congenital Heart Disease
- Adult Congenital Heart Disease
Background:
- Ebstein's anomaly is a rare congenital heart defect affecting the tricuspid valve.
- A modified surgical repair technique has been utilized since 1988.
- This technique focuses on valve mechanism restructuring without atrialized chamber plication.
Purpose of the Study:
- To present the long-term results of a modified tricuspid valve repair technique for Ebstein's anomaly.
- To evaluate the efficacy and safety of the surgical approach.
- To assess clinical outcomes and functional parameters post-repair.
Main Methods:
- A cohort of 50 patients with Ebstein's anomaly underwent tricuspid valve repair between 1988 and 2008.
- The modified technique involved valve reconstruction and, in some cases, Sebending's stitch.
- Follow-up data included survival rates, reoperations, NYHA class, maximal VO2, and right ventricular function (VTI-PA).
Main Results:
- Low early (7.1%) and late (2.4%) mortality, with deaths primarily in older, symptomatic patients.
- Significant improvements observed in NYHA class (3.1 to 1.8) and tricuspid valve insufficiency (3.2 to 1.9).
- Increased velocity-time integral of pulmonary artery flow (VTI-PA) indicating improved right ventricular function; no right ventricular aneurysms reported.
Conclusions:
- The modified tricuspid valve repair technique provides durable, positive clinical outcomes for Ebstein's anomaly.
- The approach is effective even in complex cases, potentially avoiding tricuspid valve replacement.
- Older patients with advanced NYHA class may face higher surgical risks.
Related Concept Videos
Long-patch Base Excision Repair
Since the discovery of the two BER pathways, there has been a debate about how a cell chooses one pathway over the other and the factors determining this selection. Numerous in vitro experiments have pointed out multiple determinants for the sub-pathway selection. These are:
Base Excision Repair
One of the common DNA damages is the chemical alteration of single bases by alkylation, oxidation, or deamination. The altered bases cause mispairing and strand breakage during replication. This type of damage causes minimal change to the DNA double helix structure and can be repaired by the base excision repair (BER) pathways. BER corrects damaged DNA sequences by removing the damaged base and restoring the original base sequence using the complementary strand as a template.
The first step of...
The first step of...
Mismatch Repair
Overview
Mismatch Repair
Organisms are capable of detecting and fixing nucleotide mismatches that occur during DNA replication. This sophisticated process requires identifying the new strand and replacing the erroneous bases with correct nucleotides. Mismatch repair is coordinated by many proteins in both prokaryotes and eukaryotes.
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
Nucleotide Excision Repair
Overview