High performance conductivity monitoring instrument with pulsating sensor
P Sahoo1, N Malathi, K Praveen
1Electronics and Instrumentation Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, 603102 Tamil Nadu, India. sahoop@igcar.gov.in
Abstract:
We present an unconventional but high performance pulsating conductivity monitoring instrument constructed by using a new class of sensor, viz., pulsating sensor developed in house. The design consists of a special type of logic gate oscillator (LGO) powered by 5 V direct current (dc). The conductivity cell constitutes a part of LGO. In this conductivity meter the primary signal generated from the sensor is directly in digital domain which is easily transmitted either to a personal computer or to a stand-alone embedded system. Hence it reduces the hardware components making the instrumentation highly simplified. The output of the instrument is pulse frequency which is directly related to the conductivity of solution used for measurement. The relation between pulse frequency and conductivity is determined following a multipoint calibration technique developed in our laboratory using a series of KCl standards. The performance of the instrument is demonstrated with a few examples which reveal the diverse application of this new approach of measurement technique.
Related Concept Videos
Electrical Conductivity
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...