Related Experiment Video
Updated: Jun 10, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Origin and correction of the deviations in retention times at increasing flow rate with Chromolith columns
S Pous-Torres1, J R Torres-Lapasió, M J Ruiz-Angel
1Departament de Química Analítica, Universitat de València, c/Dr. Moliner 50, 46100 Burjassot, Spain.
Abstract:
Chromoliths can be used at flow rates beyond those feasible for conventional microparticulate packed columns. Ideally, the plots of the retention time versus the inverse of delivered flow rate should exhibit y-intercept of zero. However, significant positive deviations correlating with the solute polarity were observed for several compounds chromatographed with a Chromolith column, owing to the increased system pressure. Consequently, the dead time marker exhibits a smaller deviation, making the retention factors depend on the flow rate. Chromoliths are made of a silica-based monolith encapsulated within a PEEK tube, and should suffer larger stress with pressure than stainless steel columns, tending to inflate them and increase their volume. This decreases the linear velocity inside the column, and increases the retention at relatively low pressure (<200 bar). In contrast, frictional heating, which is an issue for microparticulate columns, seems to be less significant for the highly permeable Chromoliths. The usefulness of the retention time versus the inverse of the delivered flow rate plots to measure the deviations, whatever their origin, is shown. This allows the correction of the retention times to the ideal behaviour, where the retention factors are independent of the flow rate.
Related Concept Videos
Principles Of Column Chromatography
Chromatographic Methods: Terminology
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...

