Improved ultrasonic-based sample treatment for the screening of anabolic steroids by gas chromatography/mass
M Galesio1, R Rial-Otero, J Simal-Gándara
1REQUIMTE, Departamento de Química, Faculdade de Ciências e Tecnología, Universidade Nova de Lisboa, 2829-516 Monte de Caparica, Portugal.
Abstract:
A rapid sample treatment procedure for the gas chromatography/mass spectrometry (GC/MS) determination of anabolic steroids in human urine has been developed. The new procedure makes use of ultrasonic energy to reduce reaction times and increase the overall sensitivity. The following variables affecting the performance of the ultrasonic treatment were optimised: (i) time, (ii) device, (iii) frequency, and (iv) temperature. It was found that, under an ultrasonic field, the hydrolysis of conjugated steroids with beta-glucuronidase from Escherichia coli K12 was possible with a treatment time of 10 min. The accuracy and precision of the ultrasonic method were found to be in agreement with those achieved with the conventional thermal conductivity procedure (Student's t-test; p = 0.05, n = 10). After the enzymatic hydrolysis, the derivatisation of the target compounds with trimethylsilyl (TMS) reagent, methyl-N-trimethylsilyltrifluoroacetamide (MSTFA)/NH(4)I/dithioerythritol (DTE) (1000:2:4, v/w/w), was also accelerated using ultrasonic energy. In order to test the applicability of the use of ultrasonic energy in the acceleration of the derivatisation reaction with TMS, the classic method of thermal conductivity was applied for comparative purposes to a pool of 35 androgenic anabolic steroids (AAS) and/or their metabolites. The results demonstrated that after 3 min of sonication in a Sonoreactor device (50% amplitude), 19 of the 35 compounds studied showed similar reaction yield to those obtained with the classic procedure requiring 30 min (Student's t-test; p = 0.05, n = 5); 13 increased to higher silylation yields; and for the steroids 1-testosterone, danazol and etiocholanolone-D5, the same results were obtained using a sonication time of 5 min.The overall applicability of the ultrasonic-based sample treatment method is shown by the analysis of five urine samples. The results are similar to those achieved by the routine procedure. The new method is fast, robust, and allows high sample throughput.
More Related Videos
04:19An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...