Related Experiment Video
Updated: Jun 10, 2026

Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Effect of phosphate-bonded investments on titanium reaction layer and crown fit
Sicknan Soares da Rocha1, Fabiane Nogueira, Anelise Rodolfo Ferreira Pieralini
1Department of Prevention and Oral Rehabilitation, Federal University of Goiás, Goiânia, Goiânia, GO, Brazil.
Abstract:
This study analyzed the reaction layer and measured the marginal crown fit of cast titanium applied to different phosphate-bonded investments, prepared under the following conditions (liquid concentration/casting temperature): Rema Exakt (RE) - 100%/237 degrees C, 75%/287 degrees C, Castorit Super C (CS)-100%/70 degrees C, 75%/141 degrees C and Rematitan Plus (RP)- 100%/430 degrees C (special to titanium cast, as the control group). The reaction layer was studied using the Vickers hardness test, and analyzed by two way ANOVA and Tukey's HSD tests (alpha = 0.05). Digital photographs were taken of the crowns seated on the die, the misfit was measured using an image analysis system and One-way ANOVA, and Tukey's test was applied (alpha = 0.05). The hardness decreased from the surface (601.17 VHN) to 150 microm (204.03 VHN). The group CS 75%/141 degrees C presented higher hardness than the other groups, revealing higher surface contamination, but there were no differences among the groups at measurements deeper than 150 mum. The castings made with CS - 100%/70 degrees C presented the lowest levels of marginal misfit, followed by RE -100%/237 degrees C. The conventional investments CS (100%) and RE (100%) showed better marginal fit than RP, but the CS (75%) had higher surface contamination.