Single-snapshot and intensity-resolved two-photon fluorescence measurements.

J Strohaber1, M P Poudel, A A Kolomenskii

  • 1Department of Physics, Texas A&M University, College Station, Texas 77843-4242, USA. jstroha1@physics.tamu.edu

Optics Letters
|July 29, 2010
PubMed
Summary

A new single-snapshot (SSS) method accurately measures intensity-resolved two-photon fluorescence (TPF) probabilities. This technique reveals intensity-dependent TPF behavior not observed with traditional methods.

Related Concept Videos

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
Two-Dimensional Microscopy in Microbiology01:29

Two-Dimensional Microscopy in Microbiology

Two-dimensional (2D) microscopy encompasses a range of optical techniques that capture images within a single focal plane, offering detailed representations of microscopic structures. These techniques are essential in biological and medical research, enabling the visualization of cellular and subcellular structures with different levels of contrast and specificity.There are several major types of 2D microscopy, each with strengths and applications.Bright-Field MicroscopyBright-field microscopy...