Synthetic, Multi-Layer, Self-Oscillating Vocal Fold Model Fabrication
Published on: December 2, 2011
Flow-induced vibratory response of idealized versus magnetic resonance imaging-based synthetic vocal fold models
Brian A Pickup1, Scott L Thomson
1Department of Mechanical Engineering, Brigham Young University, Provo, Utah 84602, USA.
Abstract:
Recent vocal fold vibration studies have used models defined using idealized geometry. Although these models exhibit important similarities with human vocal fold vibration, some aspects of their motion are less than realistic. In this report it is demonstrated that more realistic motion may be obtained when using geometry derived from magnetic resonance imaging (MRI) data. The dynamic response of both idealized and MRI-based synthetic vocal fold models are presented. MRI-based model improvements include evidence of mucosal wave-like motion and less vertical movement. Limitations of the MRI-based model are discussed and suggestions for further synthetic model development are offered.