Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Comparison of the use of volume fractions with other measures of concentration for quantitative spectroscopic
Howard Mark1, Ronald Rubinovitz, David Heaps
1Mark Electronics, 69 Jamie Court, Suffern, New York 10901, USA. hlmark@nearinfrared.com
Abstract:
Since the commercial development of modern near-infrared spectroscopy in the 1970s, analysts have almost invariably used units of weight percent as the measure of analyte concentration, due largely to the historical precedent from other analytical methods, including other spectroscopic techniques. The application of the CLS algorithm to a set of binary and ternary liquid mixtures reveals that the spectroscopic measurement sees the sample differently; that the measured absorbance spectrum is in fact sensitive to the volume fraction of the various components of the mixture. Because there is not a one-to-one relationship between volume fraction and other measures of analyte concentration, nor is the relationship linear, this has important implications for the application of both the CLS algorithm and the various other, more conventional, calibration algorithms that are commonly used.
More Related Videos
07:11ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis
Published on: August 19, 2021
06:50O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the method...
UV–Vis Spectroscopy: Beer–Lambert Law
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...