Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Ovine smoke/burn ARDS model: a new ventilator-controlled smoke delivery system
Cherry Ballard-Croft1, L Ryan Sumpter, Richard Broaddus
1Department of Surgery, University of Kentucky, Lexington, Kentucky 40536, USA.
Background:
Our current ovine smoke/burn acute respiratory distress syndrome (ARDS) model utilizes a manual bee smoker. This smoke delivery system lacks standardization and reproducibility, with 20% of sheep failing to meet ARDS criteria. Time to reach ARDS criteria and survival time are also variable. The mild volutrauma (15 mL/kg) applied after smoke/burn injury may also fail to induce ARDS within 24 h. We hypothesized that these inconsistencies were associated with the bee smoker and the mild volutrauma. In the current study, we addressed these problems to improve the consistency of the smoke/burn ARDS model.
Methods:
Adult female sheep (n = 10) were given a 40% total body surface area third degree cutaneous burn and 48 breaths (4 × 12) of cotton smoke under general anesthesia. A modified ventilator was then used to deliver a precise and consistent smoke volume (tidal volume) to the sheep. Additional barotrauma was induced by pressure control ventilation (40 cm H(2)0). When ARDS criteria (PaO(2)/FiO(2) < 200) were met, the ARDS Network low tidal volume ventilation protocol (6-8 mL/kg ideal body weight) was used.
Results:
Carboxyhemoglobin levels were 81.4% ± 5.6% immediately following smoke injury. All sheep met ARDS criteria within 24 h (12.5 ± 4.9 h). Mean survival time post-injury was 62.1 ± 26.4 h. White blood cells and granulocytes were significantly elevated at 24 h post-smoke/burn injury. Lung tissue at necropsy was consistent with ARDS.
Conclusions:
The refinements made to the original ovine smoke/burn ARDS model produce a more reliable time to ARDS onset, injury severity, and time of death.
More Related Videos
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...