Comparison of oscillometric pulse amplitude envelopes recorded from the locally compressed radial arteries
R Raamat1, J Talts, K Jagomägi
1Department of Physiology, University of Tartu, Tartu, Estonia. raamat@ut.ee
Abstract:
Simultaneously recorded oscillometric envelopes, obtained pneumo- and photoplethysmographically from a small local pad-type pneumatic cuff on the left and from a larger cuff on the right radial artery, were compared in 17 healthy subjects. For oscillometric estimation, specific fixed ratios based on evidence in the literature were used. The obtained envelopes for each person were shifted and aligned at the point of upper arm mean arterial pressure for this person, thus eliminating the brachial-to-radial mean blood pressure gradient and possible left-right difference. In this way, the shape of differently recorded envelopes as a determinant of the accuracy of oscillometric estimation was studied. Results showed an advantage of photoplethysmographically compared to pneumoplethysmographically recorded envelopes. For a smaller cuff (diameter 40mm), the mean difference in mmHg 'oscillometric estimate minus auscultatory reference' and standard deviation were in the case of photo recording for systolic and diastolic pressures -0.6 (6.3) and 1.2 (3.4), respectively. In the case of pneumo recording, these parameters were considerably larger, being 12.1 (11.9) and -6.2 (10.9), respectively. For a larger cuff the same tendency was revealed. Photo recording was found to be less sensitive to alterations in the cuff size and characteristic ratios.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...