Related Experiment Video
Updated: Jun 8, 2026

Sound Source Localization Testing in Single-sided Deafness Following Bone Conduction Intervention
Published on: December 20, 2024
[Study of aural rehabilitation in post-lingual deafened patients with multi-channel cochlear implant]
Jianan Li1, Xin Xi, Mengdi Hong
1Nankai University School of Medicine, Tianjin, China.
Objective:
To seek a convenient and effective method through subjective psychophysical measurements and CAP/SIR assessment. To compare the discrimination of rehabilitation between post-lingual and pre-lingual deafened patients.
Method:
Thirty-one post-lingual cochlear implantees and 59 pre-lingual cochlear implantees, the warble tone and CAP/SIR were assessed. The discrimination of threshold levels, comfortable levels and dynamic range between post-lingual and pre-lingual deafened patients in same electrodes were compared.
Result:
There was no statistic difference in warble tone, T-levels, C-levels and dynamic range in same electrodes implant after 6 months implant (P>0.05). The score of CAP and SIR in post-lingual deafened patients were more prominent.
Conclusion:
CAP and SIR is a kind of convenient and effective method to assess the ability of aural and oral. There was no discrimination in warble tone, T-levels, C-levels and dynamic range in same electrodes implant, but the ability of aural and oral in post-lingual deafened patients were more prominent.