Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Uniform Depth Channel Flow: Problem Solving01:18

Uniform Depth Channel Flow: Problem Solving

To calculate the flow rate for a trapezoidal channel, first, identify the bottom width, side slope, and flow depth of the channel. The cross-sectional area (A) corresponding to the depth of flow (y), channel bottom width (B), and side slope (θ) is determined by:Next, calculate the wetted perimeter, which includes the bottom width and the sloped side lengths in contact with the water. Using the values of the cross-sectional area and the wetted perimeter, determine the hydraulic radius by...
Body Water Content and Fluid Compartments01:19

Body Water Content and Fluid Compartments

Life's biochemical processes occur within aqueous solutions. Solutes are substances that are dissolved within these solutions. The human body contains a variety of solutes, which can differ across various body parts. These can encompass proteins—such as those responsible for clotting and carbohydrate transport—as well as electrolytes. In medicine, an electrolyte is often described as a mineral ion derived from a salt possessing an electric charge. Examples include sodium ions (Na+) and chloride...
Uniform Depth Channel Flow01:27

Uniform Depth Channel Flow

Uniform depth channel flow keeps fluid depth consistent along channels such as irrigation canals. In natural channels, such as rivers, approximate uniform flow is often assumed. This condition occurs when the channel’s bottom slope matches the energy slope, balancing potential energy lost from gravity with head loss due to shear stress. This balance prevents depth changes along the channel length, resulting in a steady, uniform flow.Uniform flow in open channels with a constant cross-section...
Rapidly Varying Flow01:24

Rapidly Varying Flow

Rapidly varying flow (RVF) in open channels is characterized by abrupt changes in flow depth over a short distance, with the rate of depth change relative to distance often approaching unity. These flows are inherently complex due to their transient and multi-dimensional nature, making exact analysis difficult. However, approximate solutions using simplified models provide valuable insights into their behavior.Key Features of Rapidly Varying FlowRVF is commonly observed in scenarios involving...
Gradually Varying Flow01:29

Gradually Varying Flow

Gradually varying flow (GVF) in open channels describes situations where water depth changes slowly along the channel due to factors like non-uniform bed slope, channel shape variations, or obstructions. This flow type occurs when the depth adjusts gradually to balance gravitational forces, shear forces, and energy requirements, resulting in a low rate of depth change.Characteristics of Gradually Varying FlowGVF is commonly observed in natural streams, rivers, and canals, where flow depth...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

HHead motion correction based on pilot tone signals in MRI - a referenceless method.

IEEE transactions on medical imaging·2026
Same author

Deep cervical lymph node analysis in central nervous system inflammatory disease.

Frontiers in immunology·2026
Same author

Focus correction in MR thermography for increased targeting precision during focused ultrasound procedures.

Magnetic resonance in medicine·2025
Same author

Physics Informed Neural Networks for Estimation of Tissue Properties from Multi-echo Configuration State MRI.

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention·2024
Same author

Characterizing dispersion in bovine liver using ARFI-based shear wave rheometry.

Biomedical physics & engineering express·2024
Same author

Preliminary Experience with Three Alternative Motion Sensors for 0.55 Tesla MR Imaging.

Sensors (Basel, Switzerland)·2024
Same journal

Structural MRI Volumetry Index for Differentiation of Progressive Supranuclear Palsy From Parkinson's Disease and Multiple System Atrophy by Automatic Segmentation: A Comparison With Magnetic Resonance Parkinsonism Index.

Journal of magnetic resonance imaging : JMRI·2026
Same journal

Integrating nnU-Net Segmentation and Clinical-Radiomics for Multicenter MRI-Based Assessment of Soft Tissue Sarcoma Grade and Ki-67 Expression.

Journal of magnetic resonance imaging : JMRI·2026
Same journal

Optimization of Respiratory Training Methods for Cardiac Magnetic Resonance Imaging.

Journal of magnetic resonance imaging : JMRI·2026
Same journal

Editorial for "Voxel-Wise Radiomics Habitat Analysis of Post-Treatment Gliomas for Noninvasive Differentiation of True Progression and Pseudoprogression".

Journal of magnetic resonance imaging : JMRI·2026
Same journal

Multiparametric Quantitative MRI of Peripheral Nerves to Differentiate Demyelinating From Axonal Polyneuropathies.

Journal of magnetic resonance imaging : JMRI·2026
Same journal

Mapping Fatty Acid Composition in the Human Knee: Short-Term Repeatability at 3T.

Journal of magnetic resonance imaging : JMRI·2026
See all related articles

Related Experiment Video

Updated: Jun 8, 2026

Long-term Behavioral Tracking of Freely Swimming Weakly Electric Fish
10:56

Long-term Behavioral Tracking of Freely Swimming Weakly Electric Fish

Published on: March 6, 2014

Fat-water separation in dynamic objects using an UNFOLD-like temporal processing.

Riad Ababneh1, Jing Yuan, Bruno Madore

  • 1Physics Department, Yarmouk University, Irbid, Jordan.

Journal of Magnetic Resonance Imaging : JMRI
|October 1, 2010
PubMed
Summary
This summary is machine-generated.

This study introduces a novel method for separating fat and water signals in dynamic MRI scans, preserving temporal resolution. This technique is crucial for various clinical applications requiring distinct fat and water imaging.

More Related Videos

An Analog Macroscopic Technique for Studying Molecular Hydrodynamic Processes in Dense Gases and Liquids
11:03

An Analog Macroscopic Technique for Studying Molecular Hydrodynamic Processes in Dense Gases and Liquids

Published on: December 4, 2017

Related Experiment Videos

Last Updated: Jun 8, 2026

Long-term Behavioral Tracking of Freely Swimming Weakly Electric Fish
10:56

Long-term Behavioral Tracking of Freely Swimming Weakly Electric Fish

Published on: March 6, 2014

An Analog Macroscopic Technique for Studying Molecular Hydrodynamic Processes in Dense Gases and Liquids
11:03

An Analog Macroscopic Technique for Studying Molecular Hydrodynamic Processes in Dense Gases and Liquids

Published on: December 4, 2017

Area of Science:

  • Magnetic Resonance Imaging (MRI)
  • Medical Physics
  • Biomedical Engineering

Background:

  • Separating fat and water signals is vital for accurate interpretation in numerous clinical MRI applications.
  • Existing methods, like the 3-point Dixon method, can significantly reduce temporal resolution, limiting dynamic imaging capabilities.

Purpose of the Study:

  • To develop a novel method for fat and water signal separation in dynamic MRI.
  • To achieve this separation with minimal loss in temporal resolution compared to conventional techniques.

Main Methods:

  • The proposed approach modulates echo time (TE) frame-by-frame to distinctly identify and separate fat signals from water signals.
  • Inspired by the UNFOLD method, this strategy modifies TE rather than sampling functions.

Main Results:

  • The method was successfully implemented and tested at both 1.5 T and 3 T field strengths.
  • The technique was validated on cardiac cine and multiframe steady-state free precession sequences, with both phantom and in vivo volunteer data.

Conclusions:

  • The developed method effectively achieves good separation of fat and water signals across all tested scenarios.
  • This approach offers a promising solution for dynamic MRI applications where preserving temporal resolution is critical.