Related Experiment Video
Updated: Jun 8, 2026

Local Field Fluorescence Microscopy: Imaging Cellular Signals in Intact Hearts
Published on: March 8, 2017
Electrophysiological differences between the epicardium and the endocardium of the left atrium
Yoav Michowitz1, Shiro Nakahara, Tara Bourke
1UCLA Cardiac Arrhythmia Center, Ronald Reagan UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, California 90095-1679, USA.
Background:
Electrophysiological properties of the atrial endocardium compared to epicardium are not well understood. The purpose of this study was to compare the electrophysiological properties and vulnerability to arrhythmia induction from these regions.
Methods And Results:
Transseptal endocardial and percutaneous epicardial mapping were performed in a porcine model (n = 7). Two opposing 4-mm electrophysiological catheters were positioned endocardially and epicardially. A circular mapping catheter (CMC) was positioned at the ostium of the common inferior pulmonary vein (CIPV) recording left atrial (LA)-PV potentials. Endocardial and epicardial effective refractory periods (ERPs) at two basic cycle lengths (CLs) of 600 and 400 ms were recorded from four anatomic locations (CIPV, LA appendage, right superior PV, and LA posterior wall). Atrial repetitive response (ARR) induction was also tested from endocardial and epicardial sites. Overall, 254 ERP measurements (mean 36.3 per animal) and 84 induction attempts (mean 12 per animal) were performed. The ERP was significantly shorter in the epicardium compared to the endocardium at basic CL of 400 ms (P = 0.006) but not at CL of 600 ms (P = 0.2). In addition, only the epicardium demonstrated ERP shortening when the CL of the basic drive was shortened (P = 0.03). ARR could be induced more often from the epicardium (P = 0.002) and fibrillatory activity with epicardial/endocardial dissociation was recorded (n = 3). Also, the earliest PV activation site on the CMC was noted to be different in 16.5% of cases during epicardial and endocardial pacing.
Conclusion:
The electrophysiological characteristics of the atrial epicardium are different from the endocardium with a shorter ERP and more frequent ARR induction by programed stimulation.
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Electrophysiology of Normal Cardiac Rhythm
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias