Related Experiment Video
Updated: Jun 7, 2026

Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
In vivo temperature measurement: tooth preparation and restoration with preheated resin composite
Frederick A Rueggeberg1, Márcia Daronch, William D Browning
1Dental Materials Section, Department of Oral Rehabilitation, Medical College of Georgia, Augusta, GA, USA.
Statement Of The Problem:
Composite preheating has shown to improve material physical properties in vitro, but no data exist on the use of this technique in vivo during placement.
Purpose:
The study aims to measure in vivo prepared tooth surface temperature during a restorative procedure using resin composite either at room temperature (23.6°C) or preheated to 54.7°C in a commercial compule heating device set to heat at 60°C.
Methods:
Class I preparations (N=3) were made on a patient requiring multiple posterior restorations. A probe containing two thermocouples was used to record temperature values at the tooth pulpal floor and 2mm higher (top of the tooth preparation/restoration) after tooth preparation (prep), acid etching (etch), placement and curing of a bonding agent (BA), and during placement of composite used at room temperature (RT) or preheated in a commercial device (Calset(TM) , AdDent Inc., Danbury, CT, USA) set to 60°C. Data were compared with two-way analysis of variance, Tukey-Kramer post hoc test (α=0.05).
Results:
No significant difference in pulpal floor temperature existed between prep (27.8°±1.3°C) and etch (26.3°±1.3°C), which were significantly lower than BA (30.5°±1.3°C) (p=0.0001). Immediate placement of preheated composite resulted in significantly higher pulpal floor (36.2°±1.9°C) (p=0.0025) and top composite temperatures (38.4°±2.2°C) (p=0.0034) than RT values (30.4°±2.2°C and 29.6°±0.9°C, respectively).
Conclusions:
In vivo use and placement of preheated resin composite resulted in temperature increase of 6° to 8°C than room temperature material. These values, however, were much lower than expected.
Clinical Significance:
Although having many potential benefits, composite preheating may not be as clinically effective in delivering resin of predetermined temperature at the time of cure as laboratory experiments would suggest. Despite only moderate composite temperature increase over use of room temperature material, preheating still provides advantages in terms of ease of handling and placement.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
