Particle-packed column versus silica-based monolithic column for liquid chromatography-electrospray-linear ion
Chiara Bignardi1, Lisa Elviri, Andrea Penna
1Dipartimento di Chimica Generale ed Inorganica, Chimica Analitica, Chimica Fisica, Università degli Studi di Parma, Viale G.P. Usberti 17/A, I-43100 Parma, Italy. lisa.elviri@unipr.it
Abstract:
A bicarbonate buffer-based extraction method for the simultaneous analysis of five nut allergens (Ana o 2, cashew-nut; Cor a 9, hazelnut; Pru 1, almond; Ara h3/4, peanut; Jug r 4, walnut) in cereals and biscuits using liquid chromatography-electrospray-linear ion trap-tandem mass spectrometry (LC-ESI-LIT-MS(2)) was developed and validated. The method was based on our earlier published LC-MS(2)-based method in a research frame aimed at the identification and determination of hidden allergens in foods by using selective biomarker peptides. A C18 particle-packed column and a silica-based C18 monolithic column were compared in terms of chromatographic performances, such as peak shape, resolution, analysis time and selectivity. The C18 particle-packed column exhibited better performances and was further used for method development and validation. By operating under MS(2) selected reaction monitoring (SRM) acquisition mode, linearity, limits of detection (LOD) and quantitation, trueness and precision were evaluated on breakfast samples enriched with a mix of the five nuts. Good linearity of the matrix matched-calibration curves was obtained and detection limit values generally varied from 14 to 55 mg nut/kg matrix. Recoveries were in the 76±4% to 94±3% range with RSD <15%. The capabilities of LIT to perform MS(n) fragmentation was exploited to improve selectivity of the analysis, and the LC-(SRM) MS(2) method was compared in terms of LOD, linearity, precision and accuracy with a LC-(SRM) MS(3) method. Finally, both the LC-MS(2) and LC-MS(3) methods were successfully applied to the analysis of nut traces in commercially available breakfast cereals and biscuits.
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Principles Of Column Chromatography
High-Performance Liquid Chromatography: Types of Detectors