Related Experiment Video
Updated: Jun 6, 2026

10:16
Digital Inline Holographic Microscopy (DIHM) of Weakly-scattering Subjects
Published on: February 8, 2014
Reduction of the zero-order intensity in binary Dammann gratings
Applied Optics
|November 10, 2010
Abstract:
The source of the reduction in the zero-order intensity in binary Dammann gratings is described as an error in the areas in the phase areas within the unit cell of the grating. Equations for determining the amount of error required to produce a specific reduction ratio are given. A two-dimensional, N = 1, Dammann grating that creates a 3 × 3 beam fan-out with a 24% reduction of the zero order provides an example of such an effect. The calculation shows agreement with the measured error.
Related Concept Videos
Downsampling
When considering a sampled sequence with zero values between sampling instants, one can replace it by taking every N-th value of the sequence. At these integer multiples of N, the original and sampled sequences coincide. This process, known as decimation, involves extracting every N-th sample from a sequence, thereby creating a more efficient sequence.
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
Phase Contrast and Differential Interference Contrast Microscopy
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Deactivation Processes: Jablonski Diagram
Luminescence, the emission of light by a substance that has absorbed energy, is a process that involves the interaction of molecules with light. The energy-level diagram, or Jablonski diagram, is a graphical representation of these interactions, illustrating the various states and transitions a molecule can undergo. In a typical Jablonski diagram, the lowest horizontal line represents the ground-state energy of the molecule, which is usually a singlet state. This state represents the energies...
