Related Experiment Video
Updated: Jun 6, 2026

On-chip Isotachophoresis for Separation of Ions and Purification of Nucleic Acids
Published on: March 2, 2012
Electrophoresis of an arbitrarily oriented toroid in an unbounded electrolyte solution
Jyh-Ping Hsu1, Chih-Hao Chou, Chao-Chung Kuo
1Department of Chemical Engineering, National Taiwan University, Taipei 10617, Taiwan. jphsu@ntu.edu.tw
Abstract:
The electrophoresis of a non-conducting rigid toroid in an unbounded Newtonian electrolyte solution having an arbitrary orientation is modeled theoretically under the condition of low surface potential. In particular, the influence of the orientation angle, defined as the angle between the applied electric field and the center line of the toroid, on its electrophoretic behavior as the thickness of double layer varies is investigated. The results of numerical simulation reveal that both the thickness of double layer and the orientation angle can influence appreciably the mobility of the toroid. In general, for a fixed orientation, the mobility of the toroid increases with decreasing double layer thickness, and for a fixed double layer thickness, the scaled electrophoresis mobility increases with increasing orientation angle. If the double layer is infinitely thin, then the present result reduces to that predicted by Smoluchowski, that is, the scaled electrophoretic mobility of the toroid is unity, and is not influenced by its shape. On the other hand, if it is infinitely thick, then the present result follows the same trend as that predicted by Henry, that is, the electrophoretic mobility of the toroid depends highly on its form effect, and the thicker the double layer the smaller that mobility. If the thickness of double layer is comparable to the radius of a toroid, the variation in the orientation angle can lead to as much as 40% difference in the mobility.
Related Concept Videos
Electrophoresis: Overview
There...
Toroids
When connected to a supply, the magnetic field generated in the toroid has field lines circular and concentric to its axis. Conventionally, the direction of this magnetic field is expressed using the right-hand rule. If the fingers of the right hand curl in the current direction, the thumb points in the...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...

