Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Non-invasive hemodynamic state monitoring using ultrasound
Aaron M Dentinger1, Ralph T Hoctor
1Ultrasound & Biomedical Laboratory, GE Global, Niskayuna, NY 12309, USA. dentinge@ge.com
Abstract:
Hemodynamic monitoring provides vital information for diagnosing and treating patients in acute clinical settings. A method is investigated to non-invasively monitor changes in the hemodynamic state. The approach utilizes short-axis ultrasound color flow imaging and processing methods to produce simultaneous waveforms for the arterial area and flow. Beat-to-beat measurements of the mean area, peak volumetric flow rate, and heart rate are extracted, and the distribution of these parameters is used to define the hemodynamic state. Changes in the hemodynamic state are detected by calculating a distance between new measurements and the current hemodynamic state, and then comparing this distance to an adaptive threshold. The distribution was modeled as a multivariate normal distribution characterized by a mean vector and a covariance matrix, and the Mahalanobis distance was used as the distance metric. The threshold level was adapted to produce a constant probability of false positives based on the current distribution. The method was evaluated by observing pharmacologically induced changes in the hemodynamic state during an in vivo animal experiment. The ultrasound-based measurements provided sufficient accuracy to discriminate between the hemodynamic states before, during and after infusion of a vasodilator. The ability to detect an acute change in the hemodynamic state was demonstrated in the transient period at the start of the infusion.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...