Related Experiment Video
Updated: Jun 6, 2026

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Primary results from the SmartDelay determined AV optimization: a comparison to other AV delay methods used in
Kenneth A Ellenbogen1, Michael R Gold, Timothy E Meyer
1Division of Cardiology, VCU School of Medicine, PO Box 980053, Richmond, VA 23298-0053, USA. kellenbogen@mcvh-vcu.edu
Background:
one variable that may influence cardiac resynchronization therapy response is the programmed atrioventricular (AV) delay. The SmartDelay determined av optimization: a comparison to other AV delay methods used in cardiac resynchronization therapy (SMART-AV) trial prospectively randomized patients to a fixed empirical AV delay (120 milliseconds), echocardiographically optimized AV delay, or AV delay optimized with SmartDelay, an electrogram-based algorithm.
Methods And Results:
a total of 1014 patients (68% men; mean age, 66 ± 11 years; mean left ventricular ejection fraction, 25 ± 7%) who met enrollment criteria received a cardiac resynchronization therapy defibrillator, and 980 patients were randomized in a 1:1:1 ratio. All patients were programmed (DDD-60 or DDDR-60) and evaluated after implantation and 3 and 6 months later. The primary end point was left ventricular end-systolic volume. Secondary end points included New York Heart Association class, quality-of-life score, 6-minute walk distance, left ventricular end-diastolic volume, and left ventricular ejection fraction. The medians (quartiles 1 and 3) for change in left ventricular end-systolic volume at 6 months for the SmartDelay, echocardiography, and fixed arms were -21 mL (-45 and 6 mL), -19 mL (-45 and 6 mL), and -15 mL (-41 and 6 mL), respectively. No difference in improvement in left ventricular end-systolic volume at 6 months was observed between the SmartDelay and echocardiography arms (P=0.52) or the SmartDelay and fixed arms (P=0.66). Secondary end points, including structural (left ventricular end-diastolic volume and left ventricular ejection fraction) and functional (6-minute walk, quality of life, and New York Heart Association classification) measures, were not significantly different between arms.
Conclusions:
neither SmartDelay nor echocardiography was superior to a fixed AV delay of 120 milliseconds. The routine use of AV optimization techniques assessed in this trial is not warranted. However, these data do not exclude possible utility in selected patients who do not respond to cardiac resynchronization therapy.
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Antiarrhythmic Drugs: Class IV Agents as Calcium Channel Blockers
Verapamil, a calcium channel blocker, inhibits calcium movement across myocardial cell membranes and vascular smooth muscle. This results in the dilation of coronary and...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation