Replacing the mercury manometer with an oscillometric device in a hypertension clinic: implications for clinical
G S Stergiou1, P Lourida, D Tzamouranis
1Hypertension Center, Third University Department of Medicine, Sotiria Hospital, Athens, Greece. gstergi@med.uoa.gr
Abstract:
Oscillometric devices are being widely used for ambulatory, home and office blood pressure (BP) measurement, and several of them have been validated using established protocols. This cross-sectional study assessed the impact on antihypertensive treatment decisions of replacing the mercury sphygmomanometer by a validated oscillometric device. Consecutive subjects attending a hypertension clinic had triplicate simultaneous same-arm BP measurements using a mercury sphygmomanometer and a validated professional oscillometric device. For each device, uncontrolled hypertension was defined as average BP ≥140/90 mm Hg (systolic/diastolic). A total of 5108 simultaneous BP measurements were obtained from 763 subjects in 1717 clinic visits. In 24% of all visits, the mercury and the oscillometric BP measurements led to different conclusion regarding the diagnosis of uncontrolled hypertension. In 4.9% of the visits, the diagnostic disagreement was considered as 'clinically important' (BP exceeding the diagnostic threshold by >5 mm Hg). These data suggest that the replacement of the mercury sphygmomanometer by a validated professional oscillometric device will result into different treatment decisions in about 5% of the cases. Therefore, and because of the known problems when using mercury devices and the auscultatory technique in clinical practise, the oscillometric devices are regarded as reliable alternatives to the mercury sphygmomanometer for office use.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Hypertension III: Clinical Manifestations and Diagnostic Studies
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.