Mycobacterium tuberculosis causing infection of an implantable biventricular defibrillator
Matthew Luckie1, Amir Zaidi, Mark Woodhead
1Manchester Heart Centre, Manchester Royal Infirmary, UK. mluckie@doctors.net.uk
Abstract:
Mycobacterial infection of implantable cardiac devices is rare, and infection of pacing system components with M. tuberculosis has been reported on only three previous occasions, involving epicardial pacing systems in two cases. We report here a pocket infection with M. tuberculosis in a transvenous biventricular defibrillator.
Related Concept Videos
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...
Tuberculosis
Endocarditis I: Introduction
Pulmonary Tuberculosis IV
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...
Pulmonary Tuberculosis II
Here is a detailed explanation of its pathophysiology:
Transmission: The process begins when a person inhales droplet nuclei containing M. tuberculosis. These are typically released into the air when an individual with pulmonary or...
Pulmonary Tuberculosis V
Latent tuberculosis infection occurs when TB bacteria are present in a person's body, but are not causing illness or symptoms. It is not contagious, and preventive treatment is crucial to avoid the progression...