Related Experiment Video
Updated: Jun 5, 2026

O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
A new PAT/QbD approach for the determination of blend homogeneity: combination of on-line NIRS analysis with PC
T Puchert1, C-V Holzhauer, J C Menezes
1Institute of Pharmacy and Molecular Biotechnology, Department of Pharmaceutical Technology and Biopharmaceutics, University of Heidelberg, Germany.
Abstract:
A novel and straightforward multivariate analytical tool for the qualitative determination of powder blend uniformity using on-line Near-Infrared Spectroscopy (NIRS) is presented. The approach combines current chemometric methods, e.g. spectral pre-processing and Principal Component Analysis (PCA), with (1) a new approach of data analysis to determine the end-point of the blending process, (2) building a design space (DS) for blend homogeneity and (3) developing a solid statistical rationale to stop blending according to Quality-by-Design (QbD) principles of FDA's Process Analytical Technology (PAT) initiative. The new approach comprises calculation of Euclidean distances between PCA scores in a multidimensional space and determination of Moving Block Standard Deviations (MBSDs) of successive Principal Component (PC) scores distances to estimate a time-window during blending where spectral variability decreases to a preset minimum. Hotelling's T(2) statistics is then used to monitor and report blend homogeneity. This technique is called "Principal Component Scores Distance Analysis" (PC-SDA). A Central Composite Design resulting in 10 batches mixed in a bin-blender (same composition, different blender fill level, different number of revolutions) was executed. NIR Chemical Imaging (NIR-CI) in combination with Symmetry Parameter Image Analysis (SPIA) was used to verify the NIRS analyzer response and assess homogeneity of all NIR-active components.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
09:57Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy
Published on: July 25, 2022
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This relationship...