Effect of photobleaching on calibration model development in biological Raman spectroscopy
Ishan Barman1, Chae-Ryon Kong, Gajendra P Singh
1Massachusetts Institute of Technology, G. R. Harrison Spectroscopy Laboratory, Laser Biomedical Research Center, Cambridge, Massachusetts 02139, USA. ishan@mit.edu
Abstract:
A major challenge in performing quantitative biological studies using Raman spectroscopy lies in overcoming the influence of the dominant sample fluorescence background. Moreover, the prediction accuracy of a calibration model can be severely compromised by the quenching of the endogenous fluorophores due to the introduction of spurious correlations between analyte concentrations and fluorescence levels. Apparently, functional models can be obtained from such correlated samples, which cannot be used successfully for prospective prediction. This work investigates the deleterious effects of photobleaching on prediction accuracy of implicit calibration algorithms, particularly for transcutaneous glucose detection using Raman spectroscopy. Using numerical simulations and experiments on physical tissue models, we show that the prospective prediction error can be substantially larger when the calibration model is developed on a photobleaching correlated dataset compared to an uncorrelated one. Furthermore, we demonstrate that the application of shifted subtracted Raman spectroscopy (SSRS) reduces the prediction errors obtained with photobleaching correlated calibration datasets compared to those obtained with uncorrelated ones.
More Related Videos
08:22Calibration-free In Vitro Quantification of Protein Homo-oligomerization Using Commercial Instrumentation and Free, Open Source Brightness Analysis Software
Published on: July 17, 2018
15:04Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
Published on: May 18, 2011
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...