Related Experiment Video
Updated: Aug 15, 2026

Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
Surgical results of 5th metatarsal stress fracture using modified tension band wiring
Kyung Tai Lee1, Young Uk Park, Ki Won Young
1Foot and Ankle Service, KT Lee's Orthopedic Hospital, 111-13, Nonhyun 2-dong Gangnam-Gu, Seoul, 135-820, South Korea.
Purpose:
The purpose of this study was to evaluate the surgical results of modified tension band wiring using two cortical screws for the treatment of fifth metatarsal stress fractures.
Methods:
Forty-two patients with Torg's type I and II fifth metatarsal stress fractures treated using the modified tension band wiring technique from 2005 to 2008 were evaluated retrospectively. All of the patients were elite athletes.
Results:
The mean length of follow-up was 26 ± 16 months (12-62 months). All patients were able to return to their previous levels of sporting activity. The mean time to union as determined by CT was 75 ± 25 days (40-150 days). However, during follow-up, there were 4 delayed unions, 1 nonunion, and 4 refractures.
Conclusion:
The described modified tension band wiring technique is a good alternative method for the surgical treatment of Torg's type I and II fifth metatarsal stress fractures.
Level Of Evidence:
Case series with no comparison group, retrospective case series, Level IV.