Related Experiment Video
Updated: Jun 4, 2026

In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
Published on: March 30, 2015
Detection of renal lesion enhancement with dual-energy multidetector CT
Amy M Neville1, Rajan T Gupta, Chad M Miller
1Department of Radiology, Duke University Medical Center, DUMC 3808, Durham, NC 27710, USA.
Purpose:
To determine whether dual-energy multidetector CT enables detection of renal lesion enhancement by using calculated nonenhanced images with spectral-based extraction in a non-body weight-restricted patient population.
Materials And Methods:
Between January 2008 and December 2009, 139 patients were enrolled in this prospective HIPAA-compliant, institutional review board-approved study. Written informed consent was obtained from all patients. After single-energy nonenhanced 120-kVp CT images were acquired, contrast material-enhanced dual-energy multidetector CT images were acquired at 80 and 140 kVp. Calculated nonenhanced images were generated by using spectral-based iodine extraction. Lesion attenuation was measured on the acquired nonenhanced, calculated nonenhanced, and 140-kVp contrast-enhanced nephrographic images. Enhancement, defined as a 15-HU or greater increase in attenuation on the nephrographic images, was assessed by using the baseline attenuation on the acquired and calculated nonenhanced images. Acquired nonenhanced versus calculated nonenhanced image attenuation, as well as enhancement values, were compared by using paired Student t tests and Bland-Altman plots.
Results:
Hypoattenuating (n = 66) and hyperattenuating (n = 28) cysts, angiomyolipomas (n = 18), and solid enhancing lesions (n = 27) were detected. Mean attenuation values for hypoattenuating cysts on the acquired and calculated nonenhanced CT images were 6.5 HU ± 5.8 (standard deviation) and 8.1 HU ± 3.1 (P = .13), respectively, with corresponding enhancement values of 1.1 HU ± 5.2 and -0.5 HU ± 6.2 (P = .12), respectively. Mean values for hyperattenuating cysts were 29.4 HU ± 5.6 on acquired images and 31.7 HU ± 5.1 on calculated images (P = .39) (corresponding enhancement, 4.7 HU ± 3.3 and 2.3 HU ± 4.1, respectively; P = .09). Mean values for fat-containing enhancing lesions were -90.6 HU ± 24.7 on acquired images and -85.9 HU ± 23.7 on calculated images (P = .57) (corresponding enhancement, 18.2 HU ± 10.1 and 13.6 HU ± 10.7, respectively; P = .19). Mean attenuation values for solid enhancing lesions were 26.0 HU ± 15.0 on acquired images and 27.7 HU ± 14.9 on calculated images (P = .45) (corresponding enhancement, 60.3 HU ± 13.1 and 58.3 HU ± 15.5, respectively; P = .38).
Conclusion:
Dual-energy CT acquisitions with spectral-based postprocessing enabled accurate detection of renal lesion enhancement across the attenuation spectrum of frequently encountered renal lesions in a non-body habitus-restricted patient population.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies II: Ultrasonography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies VII: Vascular Imaging
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Radiological Investigation I: X-ray and CT