Related Experiment Video
Updated: Jun 4, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
A Figure of Merit Comparison between Bremsstrahlung and Monoenergetic X-Ray Sources for Angiography
1Department of Radiology, University of California Davis Medical Center, Sacramento, California 95817.
Abstract:
A figure of merit (FOM) has been developed which embodies parameters related to image quality in the numerator and radiation integral dose to the patient in the denominator. In this manner, maximizing image quality and minimizing radiation dose amounts to maximizing the FOM. Furthermore, the FOM is designed to be independent of x-ray exposure (number of photons used), and this eliminates one important parameter in an optimization scenario. Monoenergetic x-ray beams (0% bandwidth) are compared with conventional Bremsstrahlung x-ray sources from a tungsten target, for angiographic imaging systems using 144 mg/cm2 Csl image intensifiers as the detector. Thus the results are applicable to both digital subtraction angiography (DSA) and digital fluoroscopic procedures involving iodine-based contrast (e.g., roadmapping). The results demonstrate improvement factors (the ratio of the best FOM of the monoenergetic beam over the best FOM of the polyenergetic beam) ranging from 2.3 to 1.4. The improvement factors averaged over four iodine contrast thicknesses (50, 100, 500, and 1000 mg/cm2) were 1.61 (σ = 0.159) for the 10 cm thick patient, 1.68 (σ= 0.172) for the 20 cm thick patient, and 1.82 (σ= 0.186) for the 30 cm thick patient. The conclusions are that monoenergetic x-ray beams are capable of delivering the same image quality at about half the radiation dose to the patient compared to conventional X-ray tubes.
Related Concept Videos
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...

