Related Experiment Video
Updated: Jun 4, 2026

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
Published on: February 20, 2021
Determination of half value layers of X-ray equipment using computed radiography imaging plates
Eiji Ariga1, Shigeki Ito, Shizuhiko Deji
1Radiological Technology Diagnostic Imaging Center, Nagoya Daini Red Cross Hospital, Myoken-cho 2-9, 466-8650 Nagoya, Aichi, Japan. a_eiji@msn.com
Abstract:
A method for determining half value layers (HVLs) of inverter-type X-ray equipment using a computed radiography (CR) systems was developed. This method is similar to the traditional method, where the air kerma (K) is measured using an ionization based dosimeter and increasing aluminum (Al) absorber thickness, but utilized an imaging plate (IP) and the sensitivity index (S number) of the CR system as the dosimeter and the dosimeter reading, respectively. The IP and the S number were calibrated using an ionization chamber having traceability to the National Standard Ionization Chamber. A modified version of the S number definition equation K=a × S(-b) was used to translate the S number to K values for X-ray beams produced using tube voltages ranging from 50 to 120 kV and additional Al filtration up to 2.5mm. The coefficient 'a' varied depending on the beam quality, while the coefficient 'b' showed a constant value of 0.991. The HVLs in the range from 1.8 to 5.5mm Al that were obtained with this method were in good agreement with those obtained with the traditional method, as uncertainties were between -7 and 4%. This method can be used to determine the HVLs of inverter-type X-ray equipment within an acceptable accuracy.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
Related Concept Videos
X-ray Imaging
Determination of Crystal Structures
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT