Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
On retentivity tuning by flow in the second column of different comprehensive two dimensional gas chromatographic
Ján Krupčík1, Pavel Májek, Roman Gorovenko
1Institute of Analytical Chemistry, Radlinskeho 9, 81237 Bratislava, Slovak Republic. jan.krupcik@stuba.sk
Abstract:
Retentivity tuning in comprehensive two dimensional GC separations of aliphatics (linear and cyclic hydrocarbons) and aromatics in gasoline by changing the carrier gas flows in the column series at constant working temperature parameters of both columns is discussed. Comprehensive 2D techniques studied include GC×GC with cryogenic and differential flow modulation and non-modulated transfer (NMT). In all configurations, the first dimension was a non-polar column and the second dimension a polar column. Using three different flows (0.6, 1.0 and 1.4mL/min) of helium carrier gas in cryogenic modulated GC×GC illustrated that, as expected, retention of the solutes on the (1)D and (2)D columns increased but the separation quality was nearly constant. A change of carrier gas pressure (p(m)=175-125kPa) on the (1)D and (2)D columns joint point at constant inlet pressure (p(i)=525kPa) in NMT, induces an increase of the carrier gas flow rate on the (1)D and a decrease on the (2)D column, respectively. The higher retentivity of the (2)D column improved the group type separation of aliphatic/cyclic hydrocarbons and aromatics and a higher distribution of aromatics on the 2D retention plane was noted. Retentivity tuning was also performed in flow modulated GC×GC by operating the (1)D column at 0.8mL/min and the (2)D column at 20 and 26mL/min. The higher retentivity at 20mL/min improved the group type separation of aliphatic/cyclic hydrocarbons and aromatics in the 2D retention plane.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-II
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...